Floor Standing Split AC 4.0 TR (48,000 BTU/h)
Share :
Banquet rooms, party venues, restaurants and large offices of about 350–450 sq ft usually need several wall units — or one Blue Star VC48HNYFA1. This commanding 1.9 m tower moves up to 1,117 CFM the length of the room, cooling at 48,000 BTU/h in summer and heating at 49,000 BTU/h in winter.
Its most practical advantage: it runs on a standard 220–240 V single-phase supply, so venues without a three-phase connection can still enjoy 4-Ton comfort. Gold colour heat exchangers on both coils resist corrosion in humid, dusty conditions.
Turbo mode handles pre-event cool-downs, Comfort Sleep and the hidden display suit quieter hours, and self-diagnosis plus the rotary compressor on R410A keep maintenance simple. Includes a 1-year warranty; Aircon Nepal positions, commissions and services it as the authorized Blue Star distributor.
TOP FEATURES
• Free-standing tower design — premium presence with no wall or ceiling civil work; simply position and connect
• Hot & Cold operation for true year-round comfort
• Gold colour heat exchangers (evaporator and condenser) for hygiene and corrosion resistance
• High-CFM, long-throw airflow to cover large open areas
• Turbo Mode for rapid pull-down cooling or fast heating
• Comfort Sleep mode for quiet, gradual overnight operation
• Hidden display for a clean, uncluttered look
• Self Diagnosis makes servicing quick and accurate
• Reliable rotary compressor with eco-friendly R410A refrigerant
• Simple, cleanable dust filter
• Warranty: 1 year against manufacturing defects
BEST SUITED FOR
Banquet and function rooms, restaurants, conference rooms and large offices of roughly 350–450 sq ft — including sites with single-phase supply only.
TECHNICAL SPECIFICATIONS
Nominal capacity | 4.0 TR |
Function | Hot & Cold (fixed speed) |
Rated cooling capacity / power input | 48,000 BTU/h / 4,800 W |
Rated EER (cooling) | 2.93 W/W |
Rated heating capacity / power input | 49,000 BTU/h / 4,700 W |
Rated COP (heating) | 3.06 W/W |
Power supply | 220–240 V / 50 Hz / 1 Phase |
Compressor / refrigerant | Rotary / R410A |
Heat exchangers | Gold colour evaporator and condenser |
Filter | Dust filter |
Air flow (T/H/M/L) | 1,117 / 1,000 / 912 / 794 CFM (wet) |
Indoor noise (T/H/M/L) | 55 / 53 / 48 / 46 dB(A) |
Indoor unit (W × D × H) / weight | 580 × 390 × 1900 mm / 50 kg |
Outdoor unit (W × D × H) / weight | 805 × 375 × 970 mm / 65 kg |
Piping — suction / liquid | Φ15.88 mm (5/8″) / Φ9 mm (3/8″) |
Max piping length / max vertical | 15 m / 8 m |
Additional refrigerant charge | 50 g/m |
Mains power connection | Outdoor unit |
Key functions | Turbo Mode, Heat Mode, Comfort Sleep, Hidden Display, Self Diagnosis |
Warranty | 1 year against manufacturing defects |
Series | Blue Star HNYFA (Fixed Speed Hot & Cold Floor Standing AC) |